4-24
Console Redirection
Selecting "Console Redirection" on the Server menu shows the following screen.
See the table below for the items.
Option Parameter Description Your Setting
BIOS Redirection
Port
[Disabled]
Serial Port A
Serial Port B
Selects the port to be used as the redirection port. The
parameters specified in Peripheral Configuration
submenu is used as address and interrupt.
ACPI Redirection
Port
[Disabled]
Serial Port A
Serial Port B
Specify the I/O port address or interrupt level used in
ACPI headless console redirection.
If [Disabled] is selected, console redirection feature is
disabled.
Baud Rate 9600
[19.2K]
38.4K
57.6K
115.2K
Specify the baud rate used for the interface with
successive hardware consoles.
Flow Control None
XON/XOFF
[CTS/RTS]
CTS/RTS+CD
Specify the flow control method.
Console Type PC ANSI
[VT100+]
VT-UTF8
Specify the console type.
Remote Console
Reset
[Disabled]
Enabled
Specify whether the reset from remote console is
enabled or disabled.