NEC Express5800/R110f-1E Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Networking NEC Express5800/R110f-1E. NEC Express5800/R110f-1E Reference Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 87
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
User's Guide
Express5800 Series
Ver.1.00
© NEC Corporation 2014
NEC ESMPRO Manager Ver.6
Command Line Interface
Chapter1 About Command Line Interface
Chapter2 Command Summary
Przeglądanie stron 0
1 2 3 4 5 6 ... 86 87

Podsumowanie treści

Strona 1 - NEC ESMPRO Manager Ver.6

User's Guide Express5800 Series Ver.1.00© NEC Corporation 2014NEC ESMPRO Manager Ver.6 Command Line Interface Chapter1 About Command Lin

Strona 2 - Contents

9 Chapter2 Command Summary 2.1 Group management Commands 2.1.1 getList Syntax: dscli getList GroupName [/g] [/x] Description: Displays the li

Strona 3

10 Displays the list of groups and components. The following shows an example. >dscli getList root group1 <GROUP> group2 <GROUP&

Strona 4

11 2.1.2 createGroup Syntax: dscli createGroup GroupName [ParentGroupName] Description: Creates a new component group. Options: GroupName Spe

Strona 5

12 2.1.5 setGroupProperty Syntax: dscli setGroupProperty GroupName PropertyName Value Description: Sets the property of a group. Options: Group

Strona 6 - About This Document

13 2.1.7 getGroupStatus Syntax: dscli getGroupStatus GroupName Description: Displays the status of a specified component group. Among all compone

Strona 7 - 1.1 System Requirements

14 2.1.8 groupPowerOn Syntax: dscli groupPowerOn GroupName [/p] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 GroupName

Strona 8 - 1.2 How to Execute Commands

15 2.1.9 groupPowerOff Syntax: dscli groupPowerOff GroupName [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 GroupName2 .

Strona 9 - Manager

16 2.1.10 groupReset Syntax: dscli groupReset GroupName [/p] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 GroupName2 ..

Strona 10 - Chapter2 Command Summary

17 2.1.11 groupPowerCycle Syntax: dscli groupPowerCycle GroupName [/p] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 Gro

Strona 11

18 2.1.12 groupShutdownOs Syntax: dscli groupShutdownOs GroupName [/force] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1

Strona 12 - 2.1.4 moveGroup

1 Contents Contents...

Strona 13 - 2.1.6 getGroupProperty

19 2.1.13 groupSetPowerRestoreDelay Syntax: dscli groupSetPowerRestoreDelay GroupName DelayTime [/x Policy] [/exs ComponentName1 ComponentName2 ...

Strona 14 - 2.1.7 getGroupStatus

20 Output: If error has occurred, the name and the error message about each error-occurred managed component is displayed. The following shows an ex

Strona 15 - 2.1.8 groupPowerOn

21 2.2 Component Management Commands 2.2.1 getServerList Syntax: dscli getServerList [/d] Description: Displays the name list of all managed co

Strona 16 - 2.1.9 groupPowerOff

22 2.2.2 getServerNameByMacAddr Syntax: dscli getServerNameByMacAddr MacAddress Description: Displays the name of the managed component that has

Strona 17 - 2.1.10 groupReset

23 2.2.4 findNewServer Syntax: dscli findNewServer StartIpAddr EndIpAddr Description: Finds BMC on managed components that are not registered on

Strona 18 - 2.1.11 groupPowerCycle

24 2.2.5 findNewServerNetAddr Syntax: dscli findNewServerNetAddr NetAddr NetMask Description: Finds BMC on managed components that are not regist

Strona 19 - 2.1.12 groupShutdownOs

25 2.2.7 deleteServer Syntax: dscli deleteServer Component [/force] Description: Deletes the specified managed component that is registered on th

Strona 20

26 2.2.9 setServerProperty Syntax: dscli setComponentProperty Component PropertyName Value Description: Sets the property of a managed component.

Strona 21

27 PropertyName Contents Value DefaultSERVER_SUBNETMASK_1 *1 Specify subnet mask of the BMC IP address. IP address format 255.255.255.0 SERVER_SU

Strona 22 - 2.2.1 getServerList

28 2.2.11 getServerGroup Syntax: dscli getServerGroup Component Description: Display the name of group that a managed component belongs to. Optio

Strona 23 - 2.2.3 getServerNameByGuid

2 2.2.26 setSensorLevel... 46 2.2.

Strona 24 - 2.2.4 findNewServer

29 2.2.13 getServerProperty Syntax: dscli getServerProperty Component PropertyName Description: Displays the specified property of a managed compo

Strona 25 - 2.2.6 createServer

30 BMC LAN2 IP Address Extra BMC IP address to connect to the managed component via LAN. BMC LAN2 Subnet Mask Subnet mask of the extra BMC IP addre

Strona 26 - 2.2.8 checkConnection

31 2.2.15 getDeviceId Syntax: dscli getDeviceId Component Description: Obtains management controller information of the managed component. Option

Strona 27 - 2.2.9 setServerProperty

32 2.2.17 getProductName Syntax: dscli getProductName Component Description: Obtains the product name and serial number of a managed component. O

Strona 28 - 2.2.10 moveServer

33 2.2.19 setShutdownPolicy Syntax: dscli setShutdownPolicy Component KeyName Value Description: Changes shutdown policy of NEC ESMPRO Agent Exten

Strona 29 - 2.2.12 setCurrentPort

34 KeyName Contents Value SCH_SHUTDOWN_WAIT Specify delay time in seconds to shutdown the managed component after shutdown OS command is issued. *

Strona 30 - 2.2.14 getServerInfo

35 2.2.21 setPowerRestoreDelay Syntax: dscli setPowerRestoreDelay Component DelayTime [/x Policy] Description: Changes the power option that speci

Strona 31

36 2.2.22 getPowerRestoreDelay Syntax: dscli getPowerRestoreDelay Component Description: Obtains power option that specifies working of a managed

Strona 32 - 2.2.16 getGuid

37 /x ModuleNo Specify the CPU/IO module number (0 or 1) if the managed component is a fault tolerant server. This parameter is valid for the networ

Strona 33 - 2.2.18 getSoftwareInfo

38 KeyName Contents Value CFG_LAN_MANAGE1_IP_LAN1 LAN1: Alert Receiver/ management PC(1) IP address IP address format CFG_LAN_MANAGE2_ALERT_LAN1 L

Strona 34 - 2.2.19 setShutdownPolicy

3 2.6.7 clearPermitIpAddr ...82 2.7 Use

Strona 35 - 2.2.20 getShutdownPolicy

39 KeyName Contents Value CFG_SERIAL_BAUDRATE WAN/Direct: Baud Rate 1: 9600bps 2: 19.2Kbps 3: 57.6Kbps 4: 115.2Kbps CFG_SERIAL_FLOW_CONTROL WAN/D

Strona 36 - 2.2.21 setPowerRestoreDelay

40 KeyName Contents Value CFG_SERIAL_MANAGE2_IP WAN/Direct Alert Receiver (2) IP address IP address format CFG_SERIAL_MANAGE3_IP WAN/Direct Alert

Strona 37 - 2.2.23 setBmcInfo

41 KeyName Contents Value CFG_NETWORK_DNS_SERVER Network Property: Basic DNS Server IP address format CFG_NETWORK_HOST_NAME Network Property: Basic

Strona 38

42 KeyName Contents Value CFG_MAIL_ALERT_SERVER Alert Mail Alert: SMTP Server SMTP Server Up to 255 characters CFG_MAIL_ALERT_PORT Alert Mail Alert

Strona 39

43 KeyName Contents Value CFG_SNMP_ALERT Alert SNMP Alert: Alert 0: Disabled 1: Enabled CFG_SNMP_COMPUTER_NAME Alert SNMP Alert: Computer Name Up t

Strona 40

44 KeyName Contents Value CFG_MISCELLANEOUS_PEF Other: Platform Event Filter Platform Event Filter 0: Disabled 1: Enabled

Strona 41

45 2.2.24 getBmcInfo Syntax: dscli getBmcInfo Component [/x ModuleNo] Description: Obtains BMC configuration information of a specified managed co

Strona 42

46 2.2.25 setAuthKey Syntax: dscli setAuthKey Component OldPassword NewPassword SelectAuthKey Description: Changes the authentication key, PPP ser

Strona 43

47 Type Specify an alert type. SNMP: SNMP alert MAIL: MAIL alert SensorName Specify the key name of sensor. See the following list. Level1 Specify

Strona 44 - Receiver

48 SensorName Contents Level1 Level2 Level3COOL_DEV_ABNORMAL Cooling Device (Monitoring Abnormal State) OK OK OK TRANSITION_PW_SAVE Transition t

Strona 45

4 Trademarks EXPRESSBUILDER and NEC ESMPRO are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Vista, Windows Server are regi

Strona 46 - 2.2.24 getBmcInfo

49 See the following list for a fault tolerant server. OK : Enable to change, NG : Disable to change SensorName Contents Level1 Level2 Level3TE

Strona 47 - 2.2.26 setSensorLevel

50 SensorName Contents Level1 Level2 Level3PROCESSOR_DEGRADED Processor(Monitoring Degraded State) NG NG OK MODULE_BOARD_DEGRADED Module/Board(Mo

Strona 48

51 2.2.27 getSensorLevel Syntax: dscli getSensorLevel Component Type Description: Obtains separate setting at the alert level of BMC configuration

Strona 49

52 2.2.28 getAgentExtensionLog Syntax: dscli getAgentExtensionLog Component Description: Obtains the application logs of the NEC ESMPRO Agent Exte

Strona 50

53 2.2.29 testAlert Syntax: dscli testAlert Component Target Description: Executes an alert test. You can confirm the result of test using 2.2.3

Strona 51

54 2.2.30 getTestAlertStatus Syntax: dscli getTestAlertStatus Component Target Description: Obtains the state of an alert test. The parameter supp

Strona 52 - 2.2.27 getSensorLevel

55 2.2.32 getPowerStatus Syntax: dscli getPowerStatus Component Description: Obtains the power state of a specified managed component. Options: Co

Strona 53 - 2.2.28 getAgentExtensionLog

56 2.2.34 getPanelInfo Syntax: dscli getPanelInfo Component [/x ModuleNo] Description: Obtains the following state as the front panel information

Strona 54 - 2.2.29 testAlert

57 2.2.35 powerOn Syntax: dscli powerOn Component [/p] Description: Turns on a specified managed component. If the POWER switch needs to be presse

Strona 55 - 2.2.31 getServerStatus

58 2.2.37 reset Syntax: dscli reset Component [/p] Description: Forcibly resets a specified managed component. IMPORTANT:  Since remote power c

Strona 56 - 2.2.33 getStatusLamp

5 About This Document This document introduces command line interface of the component management utility "NEC ESMPRO Manager". Before at

Strona 57 - 2.2.34 getPanelInfo

59 2.2.38 powerCycle Syntax: dscli powerCycle Component [/p] Description: Forcibly turns off a specified managed component and then turns it on.

Strona 58 - 2.2.36 powerOff

60 2.2.39 shutdownOs Syntax: dscli shutdownOs Component [/force] Description: Shut downs the operating system on a managed component. This com

Strona 59 - 2.2.37 reset

61 2.2.41 clearSel Syntax: dscli clearSel Component [/force] Description: Clears the System Event Log (SEL) area on a managed component. Options:

Strona 60 - 2.2.38 powerCycle

62 FileName Specify the filename with path name for saving the IPMI information. /x ModuleNo Specify the CPU/IO module number (0 or 1) if the manage

Strona 61 - 2.2.40 dumpSwitch

63 /x ModuleNo Specify the CPU/IO module number (0 or 1) if the managed component is a fault tolerant server. If you omit this parameter for the faul

Strona 62 - 2.2.43 getIpmiInfo

64 2.2.47 setBmcIpSync Syntax: dscli setBmcIpSync Component Value Description: Changes BMC IP Address Synchronization of NEC ESMPRO Agent Extensio

Strona 63 - 2.2.45 getSensorStatus

65 2.2.49 getBladeSlotId Syntax: dscli getBladeSlotId Component Description: Execute 2.2.41 getIpmiInfo command previously. Obtains enclosure ID

Strona 64 - 2.2.46 getConsoleLog

66 2.2.51 getBmcUserList Syntax: dscli getBmcUserList Component Description: Displays a list of user accounts that is set in the BMC configuration

Strona 65 - 2.2.48 getBmcIpSync

67 2.2.52 setBmcUserInfo Syntax: dscli setBmcUserInfo Component UserId KeyName Values Description: Changes the user account information for the BM

Strona 66 - 2.2.50 deleteBmcUser

68 2.2.54 setPowerRestorePolicy Syntax: dscli setPowerRestorePolicy Component Policy Description: Changes AC-Link policy that specifies working of

Strona 67 - 2.2.51 getBmcUserList

6 Chapter1 About Command Line Interface The NEC ESMPRO Manager command line interface provides a set of commands that can control managed component

Strona 68 - 2.2.53 getBmcUserInfo

69 2.2.56 getSystemFtLamp Syntax: dscli getSystemFtLamp Component Description: Obtains the state of System FT LED if the managed component is a fa

Strona 69 - 2.2.55 getPowerRestorePolicy

70 2.3 EM Card Management Commands The following component management commands can be used for an EM card. However, the MAC address cannot be spec

Strona 70 - 2.2.56 getSystemFtLamp

71 2.3.2 getEmActiveState Syntax: dscli getEmActiveState EmCard Description: Displays state of active/standby of the specified EM card. Options:

Strona 71 - 2.3.1 getEmCardList

72 2.3.4 getEmStatusLamp Syntax: dscli getEmStatusLamp EmCard [/x SwmSlotNumber] Description: Obtains the state of a specified EM card or the swi

Strona 72 - 2.3.3 identifyEm

73 2.4 Chassis Management Commands 2.4.1 getBladeEnclosureList Syntax: dscli getBladeEnclosureList Description: Displays the list of the blade

Strona 73 - 2.3.4 getEmStatusLamp

74 The following shows an example. CPU Blade: 1: SERVER_0001 2: SERVER_0002 3,4: SERVER_0003 (Double-wide) 5: Not installed 6: Not registered 7:

Strona 74 - 2.4.2 getChassisSlotState

75 2.4.4 setChassisProperty Syntax: dscli setChassisProperty ChassisName PropertyName Value Description: Sets the chassis property of a chassis.

Strona 75 - 2.4.3 getChassisInfo

76 2.4.6 setBladeAutoSetting Syntax: dscli setBladeAutoSetting ChassisName SlotNumber PropertyName Value Description: This command is effective o

Strona 76 - 2.4.5 getChassisProperty

77 2.4.7 getBladeAutoSetting Syntax: dscli getBladeAutoSetting ChassisName SlotNumber Description: This command is effective only to the chassis

Strona 77 - 2.4.6 setBladeAutoSetting

78 2.5 Communication Management Commands 2.5.1 connect Syntax: dscli connect Component Description: Connects to a managed component with via mo

Strona 78 - 2.4.7 getBladeAutoSetting

7 1.2 How to Execute Commands To execute a command, enter the command following the command prompt as shown below. dscli CommandName [Option, …] d

Strona 79 - 2.5.3 getConnectionStatus

79 2.6 Environment Setting Commands 2.6.1 setOption Syntax: dscli setOption OptionName Value Description: Sets an option of the NEC ESMPRO Mana

Strona 80 - 2.6.1 setOption

80 2.6.2 getOption Syntax: dscli getOption OptionName Description: Displays an option of the NEC ESMPRO Manager. Options: OptionName Specify a

Strona 81 - 2.6.3 getPermitIpAddrList

81 2.6.4 isPermitIpAddr Syntax: dscli isPermitIpAddr CheckIpAddr Description: Checks whether a specified IP address is permitted for login from a

Strona 82 - 2.6.6 removePermitIpAddr

82 2.6.7 clearPermitIpAddr Syntax: dscli clearPermitIpAddr Description: Removes all IP address ranges in which login from a Web client is permit

Strona 83 - 2.6.7 clearPermitIpAddr

83 2.7 User Management Commands 2.7.1 createUser Syntax: dscli createUser UserName Password Description: Registers a new user that can login to

Strona 84 - 2.7.3 getUserList

84 2.7.4 setUserProperty Syntax: dscli setUserProperty UserName PropertyName Value Description: Sets a property of a specified user. Options: Us

Strona 85 - 2.7.4 setUserProperty

85 PropertyName Contents Value Default Admini-strator Ope-ratorUL_REMOTE_BATCH Specify the enable/disable of Remote Batch function. 0: Disabled 1

Strona 86 - 2.7.5 getUserProperty

86 2.8 Other Commands 2.8.1 getApplicationLog Syntax: dscli getApplicationLog [Number] Description: Displays the latest application logs up to

Strona 87 - 2.8 Other Commands

8 1.3 Execution Results All the commands return the end status. If an error has occurred, they return an error message. The end status of all the c

Komentarze do niniejszej Instrukcji

Brak uwag