ncy
rity is set
Value set after Consistency Check Priority is set(Select a
of high, middle, and low)
Check the execution result by using
Step 1
Execute "optctrl" command with -ccp
option and the following parameters.
Number of the RAID Controller for which Consiste
Check Prio
> raidcmd optctrl -c=1 -ccp=m e
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Corporation
Model : MegaRAID SAS PCI Express(TM)
ROMB
Firmware Version : 1.12.02-0342
Cache Size : 128MB
Battery Status : Normal
Patrol Read Priority : Low
Buzzer Setting : Enable
1
iddl
2
value out
Step 2
Rebuild Priority : High
Consistency Check Priority : Middle
Patrol Read : Enable
"property" command.
>