NEC Express5800/R110f-1E Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Kontrolery RAID NEC Express5800/R110f-1E. NEC Express5800/R110f-1E Appendix Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 10
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Appendix C : Logs/Events
The lists of log and event, alert messages that Universal RAID Utility logs to RAID Log and OS Log are described in this
section.
[Event Source, Alert Type]
OS event source name: raidsrv
Source Name on NEC ESMPRO Manager (Windows): raidsrv
Source Name on NEC ESMPRO Manager (Linux, VMware): RAIDSRV
Alert Type : URAIDUTL
[Log]
Mark Description
R Universal RAID Utility logs this event to RAID Log.
O Universal RAID Utility logs this event to OS log.
[Alert]
Mark Description
M and MA Universal RAID Utility sends this event to NEC ESMPRO Manager as alert.
[ A
ddress ] description in [Description]
The [ Address ] description is different from the category of event.
Category of Event Type Description
RAID Controller
Battery
Flash Backup Unit
1 [CTRL:%1(ID=%2)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
Physical Device 2 [CTRL:%1(ID=%2) PD:%3(ID=%4) %5%6]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Physical Device
%4 : ID of Physical Device
%5 : Vendor and Model of Physical Device
%6 : Firmware Version of Physical Device
Logical Drive 3 [CTRL:%1(ID=%2) LD:%3(ID=%4)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
Enclosure 4 [CTRL:%1(ID=%2) ENC:%3]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
Power Supply Unit in Enclosure 5 [CTRL:%1(ID=%2) ENC:%3 POW:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Power Supply Unit
Fan Unit in Enclosure 6 [CTRL:%1(ID=%2) ENC:%3 FAN:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Fan Unit
Przeglądanie stron 0
1 2 3 4 5 6 7 8 9 10

Podsumowanie treści

Strona 1 - Appendix C : Logs/Events

1 Appendix C : Logs/Events The lists of log and event, alert messages that Universal RAID Utility logs to RAID Log and OS Log are described in this

Strona 2 - [priority, facility]

10 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0801 (C0000321) Fatal It became unable to manage the RAID System due

Strona 3

2 [priority, facility] The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX. kind priority faci

Strona 4

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0201 (400000C9) Information [Address Type 1 ] The buzzer of RAID Controll

Strona 5

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0219 (400000DB) Information [Address Type 1 ] RAID Controller property wa

Strona 6

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0316 (4000013C) Information [Address Type 2 ] Dedicated Hot Spare remove

Strona 7

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0402 (80000192) Warning [Address Type 3 ] Logical Drive is Degraded. RO

Strona 8

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0418 (400001A2) Information [Address Type 3 ] Background Initialization

Strona 9

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0435 (400001B3) Information [Address Type 3 ] Power Save Mode of Logical

Strona 10

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0517 (80000205) Warning [Address Type 1 ] A Fatal Error happened to Flas

Komentarze do niniejszej Instrukcji

Brak uwag