5
Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method
0320
(C0000140)
Fatal [Address Type 2 ] Medium Error was detected in Physical
Device but could not correct. %1
%1 : Logical Block Address
RO MA Physical Device Medium
Error(Uncorrectable)
Please replace the Physical Device if too many errors
are detected on a Physical Device.
0321
(40000141)
Information [Address Type 2 ] Rebuild was paused. R
0322
(40000142)
Information [Address Type 2 ] Rebuild was resumed. R
0323
(40000143)
Information [Address Type 2 ] Rebuild was queued. R
0324
(80000144)
Warning [Address Type 2 ] Medium Error was detected in Physical
Device. %1
%1 : Logical Block Address
RO MA Physical Device Medium
Error Detected
Please replace the Physical Device if too many errors
are detected on a Physical Device.
0325
(40000145)
Information [Address Type 2 ] Physical Device Power Status is
Transitioning.
RO
0326
(40000146)
Information [Address Type 2 ] Physical Device Power Status is On. RO
0327
(40000147)
Information [Address Type 2 ] Physical Device Power Status is Power
Saving.
RO
0328
(C0000148)
Fatal [Address Type 2 ] Physical Device Power Status Change
failed.
RO MA Physical Device Power
Status Change Failed
Please replace the Physical Device.
(40000191)
[Address Type 3 ] Logical Drive is Online.
0402
(80000192)
Warning [Address Type 3 ] Logical Drive is Degraded. RO MA Logical Drive Degraded
If there is Hot Spare, RAID System will rebuild
automatically. If there is not it, please replace the
Physical Device and rebuild it.
(C0000193)
[Address Type 3 ] Logical Drive is Offline.
Please replace the Physical Device and remake the
Logical Drive. Next restore the backup data to the
Logical Drive.
0404
(40000194)
Information [Address Type 3 ] Initialization was started. R
(40000195)
[Address Type 3 ] Initialization completed.
0406
(C0000196)
Fatal [Address Type 3 ] Initialization failed. RO MA Initialization Failed Please retry Initialization. If Initialization failed
repeatedly, the RAID System may have some kind of
problem. Please deal with the problem of the RAID
System.
0407
(40000197)
Information [Address Type 3 ] Initialization was stopped. R
0409
(40000199)
Information [Address Type 3 ] Consistency Check was started. R
Komentarze do niniejszej Instrukcji