Strona 1 - External Control

1 External Control for LCD8205 Revision Date History Ver. 1.0 Dec.9.2008 The first edition.

Strona 2 - 3.1. Communication timing

10 8th -9thbytes) Type: Operation type code 00h: Set parameter 01h: Momentary Like the Auto Setup function which automatically changes the parameter

Strona 3

11 2nd-3rdbytes) Result code ASCII '0''0' (30h, 30h): No Error. ASCII '0''1' (30h, 31h): Unsupported operati

Strona 4 - 4.2. Optional Command List

12 5.3. VCP Command 5.3.1. VCP (OP code page/OP code) List Item OP code page OP code Parameter Remarks Picture Mode 02h 1Ah 0: User 1: Dynami

Strona 5

13 OSD Tone 02h B8h 0: None 1: Off(Opaque) 2: ON BG Gray 02h DFh 0: black / Max:white Fan Control 02h 7Dh 0: None 1: Auto 2: Always On Fan c

Strona 6

14 5.3.2. How to change the “Brightness” setting. The following is a sample of procedures to control the monitor, these are examples

Strona 7

15 Step 3. The controller request the monitor to change the Brightness setting Header SOH (01h): Start Of Header '0' (30h): Reserved Monit

Strona 8 - 5.1.3. Check code

16 SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to store the setting. Ex.) If Monitor I

Strona 9 - Message type

17 5.4. Commands message 5.4.1. Power Command 5.4.2. Power status read 1) The controller requests the monitor to reply a current power status. H

Strona 10

18 '0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types. '0'-'0'-'0'-&ap

Strona 11

19 Note.) The maximum data length that can be written to the monitor at a time is 32bytes. Ex.) The byte data 20h is encoded as ASCII

Strona 12 - 5.3. VCP Command

2 1. Application - This document defines the communications method for control of the LCD8205 monitor. 2. Connectors and Writing Connec

Strona 13

20 6. Optional Commands 6.1. Communication Format (for Optional Commands) 6.1.1. Virtual Remote Control 6.1.2. Setting Parameters to Juno 6.1.3.

Strona 14

21 6.2. Control Command Packet 6.2.1. System Parameter Direct Settings/Read Packet CMD Data1 Data2 Data3 Data4 Data5 Range Command Target ID

Strona 15

22 0x33 MAX_ILLUMINANCE(2) 0 200 0x34 MIN_ILLUMINANCE(3) 0 200 0x35 AUTO_DIM 0 1 0x37 CURTEMP_MAIN 0 - 0x38 CURTEMP_AUX 0 - 0x39 TEMP_THRES

Strona 16

23 6.3. Control Examples at Master PC 6.3.1. Set Input Source to RGB Input 6.3.2. Read Power State

Strona 17 - 5.4. Commands message

24 7. Typical procedure example The following is a sample of procedures to control the monitor, these are examples of “ Set parameter” , “ Get para

Strona 18

25 7.2. “CURRENTSOURCE” Control procedure 7.2.1. Current Source Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monit

Strona 19 - CR (0Dh): End of packet

26 7.3. “PC_PICTUREMODE” Control procedure 7.3.1. Picture Control (PC, Digital video mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Ta

Strona 20 - 6. Optional Commands

27 7.4. “COLORTEMP” Control procedure 7.4.1. color temperature Control (PC, Digital video mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF

Strona 21 - 6.2. Control Command Packet

28 7.5. “CONTRAST” Control procedure 7.5.1. Contrast Control (PC, Digital video mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target

Strona 22 - Notice

29 7.6. “BRIGHTNESS” Control procedure 7.6.1. Brightness Control (PC, Digital video mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Tar

Strona 23

3 4. Command List 4.1. Basic Command List 4.1.1. VCP Command Command Page Communication Format Picture Mode p.12-p.16 Brightness p.12-p.16 Co

Strona 24 - 7. Typical procedure example

30 7.7. “SHARPNESS” Control procedure 7.7.1. Sharpness Control (PC, Digital video mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Targe

Strona 25

31 7.8. “RF_PICTUREMODE” Control procedure 7.8.1. Picture Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0

Strona 26

32 7.9. “ RF_COLORTONE ” Control procedure 7.9.1. Color temperature Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5

Strona 27

33 7.10. “ RF_CONTRAST ” Control procedure 7.10.1. Contrast Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5 Command

Strona 28

34 7.11. “ RF_BRIGHTNESS ” Control procedure 7.11.1. Brightness Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5 Com

Strona 29

35 7.12. “ RF_COLOR ” Control procedure 7.12.1. Color Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5

Strona 30

36 7.13. “ NTSC_TINT ” Control procedure 7.13.1. TINT Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5

Strona 31

37 7.14. “ RF_SHARPNESS ” Control procedure 7.14.1. Sharpness Control (AV , S-video , Component mode) CMD Data1 Data2 Data3 Data4 Data5 Comma

Strona 32

38 7.15. “SCALEMODE” Control procedure 7.15.1. Current Scale mode Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Mo

Strona 33

39 7.16. “ USERRED ” Control procedure 7.16.1. USERRED Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0

Strona 34

4 4.2. Optional Command List Command Page Communication Format LANGUAGE p.24 CURRENTSOURCE p.25 PC_PICTUREMODE p.26 COLORTEMP p.27 CONTRAST p.28

Strona 35

40 7.17. “ USERGREEN ” Control procedure 7.17.1. USERGREEN Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor I

Strona 36

41 7.18. “ USERBLUE ” Control procedure 7.18.1. USERBLUE Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID

Strona 37

42 7.19. “MUTE” Control procedure 7.19.1. Mute Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0x00) CMD

Strona 38

43 7.20. “SOUNDSTD” Control procedure 7.20.1. Sound STD Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (

Strona 39

44 7.21. “ AUTOVOLUME ” Control procedure 7.21.1. Auto Volume Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monito

Strona 40

45 7.22. “ VOLUME ” Control procedure 7.22.1. VOLUME Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0x0

Strona 41

46 7.23. “ BALANCE ” Control procedure 7.23.1. BALANCE Control (sound L+R balance) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0

Strona 42

47 7.24. “ Equalizer ” Control procedure 7.24.1. Equalizer Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor I

Strona 43

48 7.25. “ ONHOUR ” Control procedure 7.25.1. ONHOUR Control (Power on time) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) M

Strona 44

49 7.26. “ ONMINUTE ” Control procedure 7.26.1. ONMINUTE Control (Power on time) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x8

Strona 45

5 5. Basic Commands 5.1. Communication Format (for Basic Commands) The command packet consists of four parts, Header, Message, Chec

Strona 46

50 7.27. “ ONTIMEONOFF ” Control procedure 7.27.1. ONTIMEONOFF Control ( Power ON time control ) CMD Data1 Data2 Data3 Data4 Data5 Command (0

Strona 47

51 7.28. “ ONTIMEVOL ” Control procedure 7.28.1. ONTIMEVOL Control (Power ON Volume) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target

Strona 48

52 7.29. “ OFFHOUR ” Control procedure 7.29.1. OFFHOUR Control (Power OFF time) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88

Strona 49

53 7.30. “ OFFMINUTE ” Control procedure 7.30.1. OFFMINUTE Control (Power OFF time) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (

Strona 50

54 7.31. “ OFFTIMEONOFF ” Control procedure 7.31.1. OFFTIMEONOFF Control ( Power OFF time control ) CMD Data1 Data2 Data3 Data4 Data5 Command

Strona 51

55 7.32. “ HALFTONE ” Control procedure 7.32.1. HALFTONE Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0

Strona 52

56 7.33. “ BLUESCREEN ” Control procedure 7.33.1. BLUESCREEN Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor I

Strona 53

57 7.34. “ PIXELSHIFT_EN ” Control procedure 7.34.1. PIXELSHIFT_EN Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Mon

Strona 54

58 7.35. “ WIPER_EN ” Control procedure 7.35.1. WIPER Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0x00

Strona 55

59 7.36. “ BGGRAY ” Control procedure 7.36.1. BGGRAY Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0x00)

Strona 56

6 “Monitor ID” to “Destination Address” conversion table is as follows, Monitor ID Destination Address (ASCII) Monitor ID Destination Address (A

Strona 57

60 7.37. “ POWER ”(read only) Control procedure 7.37.1. Current Power state read CMD Data1 Data2 Data3 Data4 Command (0xF4) Target (0x89) Moni

Strona 58

61 7.38. “ CURHOUR ” Control procedure 7.38.1. CURHOUR Control (Current time) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88)

Strona 59

62 7.39. “ CURMINUTE ” Control procedure 7.39.1. CURMINUTE Control (Current time) CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x

Strona 60

63 Dimming Control (7.40 ~ 7.42) Auto dimming control mode. Refer to diagram of DBLC On : Dimming varies by light ambient level Off : Dimming va

Strona 61

64 7.40. “ MAX_ILLUMINANCE ” Control procedure 7.40.1. MAX_ILLUMINANCE Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x8

Strona 62

65 7.41. “ MIN_ILLUMINANCE ” Control procedure 7.41.1. MIN_ILLUMINANCE Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x8

Strona 63

66 7.42. “ AUTO_DIM ” Control procedure 7.42.1. AUTO_DIM Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID

Strona 64

67 Fan Control (7.43 ~ 7.47) There are three kind of fan control mode as below; Please refer to diagram of ATC On : Always activates fan Auto : Auto

Strona 65

68 7.43. “ CURTEMP_MAIN ” Control procedure 7.43.1. Current main Temperature state read CMD Data1 Data2 Data3 Data4 Command (0xF4) Target (0x89

Strona 66

69 7.45. “ TEMP_THRESHOLD ” Control procedure 7.45.1. TEMP_THRESHOLD Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88)

Strona 67

7 2)Get Parameter reply The monitor will reply with the status of the requested item specified by the controller in the “Get parameter m

Strona 68

70 7.46. “ TEMP_HYSTERESIS ” Control procedure 7.46.1. TEMP_ HYSTERESIS Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x

Strona 69

71 7.47. “ FAN_CONTROL ” Control procedure 7.47.1. FAN_CONTROL Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monit

Strona 70

72 (5.48 ~ 5.53)

Strona 72 - (5.48 ~ 5.53)

74 7.48. “ SETX ” Control procedure 7.48.1. SETX Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0x00) C

Strona 73

75 7.49. “ SETY ” Control procedure 7.49.1. SETY Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0x00) CM

Strona 74

76 7.50. “ SETXMAX ” Control procedure 7.50.1. SETXMAX Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0

Strona 75

77 7.51. “ SETYMAX ” Control procedure 7.51.1. SETYMAX Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0

Strona 76

78 7.52. “ SETXGAP ” Control procedure 7.52.1. SETXGAP Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0

Strona 77

79 7.53. “ SETYGAP ” Control procedure 7.53.1. SETYGAP Control CMD Data1 Data2 Data3 Data4 Data5 Command (0xF5) Target (0x88) Monitor ID (0

Strona 78

8 5.1.3. Check code Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH. Dn+1 = D1 XOR D

Strona 79

9 5.2. Message type 5.2.1. Get current Parameter from a monitor. Send this message when you want to get the status of a monitor. For the s