NEC Express5800/R110d-1E Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Kontrolery RAID NEC Express5800/R110d-1E. NEC Express5800/R110d-1E Appendix Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 8
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Appendix C : Logs/Events
The list of log and event , alert messages that Universal RAID Utility logs to RAID Log and OS Log.
[Event Source, Alert Type]
Source Name of Event Log (only Windows) : raidsrv
Alert Type : URAIDUTL
[Log]
Mark
Description
R Universal RAID Utility logs this event to RAID Log.
O Universal RAID Utility logs this event to OS log.
[Alert]
Mark Description
M and MA Universal RAID Utility send this event to NEC ESMPRO Manager as alert.
The [ Address ] description is different from the category of event.
[
Address
] description in [Description]
Category of Event Type Description
RAID Controller
Battery
1 [CTRL:%1(ID=%2)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
Physical Device 2 [CTRL:%1(ID=%2) PD:%3(ID=%4 ENC=%5 SLT=%6) %7%8]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Physical Device
%4 : ID of Physical Device
%5 : Enclosure Number of Physical Device
%6 : Slot Number of Physical Device
%7 : Vendor and Model of Physical Device
%8 : Firmware Version of Physical Device
Logical Drive 3 [CTRL:%1(ID=%2) LD:%3(ID=%4)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
Enclosure 4 [CTRL:%1(ID=%2) ENC:%3]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
Power Supply Unit in Enclosure 5 [CTRL:%1(ID=%2) ENC:%3 POW:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Power Supply Unit
Fan Unit in Enclosure 6 [CTRL:%1(ID=%2) ENC:%3 FAN:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Fan Unit
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Appendix C : Logs/Events

1 Appendix C : Logs/Events The list of log and event , alert messages that Universal RAID Utility logs to RAID Log and OS Log. [Event Source, Ale

Strona 2 - [priority, facility]

2 The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX. [priority, facility] kind priority facil

Strona 3

3 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0201 (400000C9) Information [Address Type 1 ] The buzzer of RAID Cont

Strona 4

4 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0302 (4000012E) Information [Address Type 2 ] Physical Device is Read

Strona 5

5 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0322 (40000142) Information [Address Type 2 ] Rebuild was resumed. R

Strona 6

6 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0413 (C000019D) Fatal [Address Type 3 ] Data Inconsistency was detect

Strona 7

7 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0428 (400001AC) Information [Address Type 3 ] Initialization was queu

Strona 8

8 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0604 (C000025C) Fatal [Address Type 4 ] The temperature of Enclosure

Komentarze do niniejszej Instrukcji

Brak uwag