CHAPTER 3 SYSTEM DATA PROGRAMMING
Event Based CCIS Programming
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 125
DESCRIPTION DATA
Specify the voice channel and common
signaling channel route as the Event
Based CCIS route.
(1)
(2)
YYY=135
00-63: Trunk Route No.
0: Event Based CCIS Route
Specify which number is adopted for
sending CCIS channel number of virtual
trunks between the offices, either
subaddress number or ISDN Indial dialed-
in digits.
(1)
(2)
YYY=143
00-63: Trunk Route No.
0: By Subaddress
1: By dialed-in digits
Specify the Information Transfer Capability
of the ISDN line used for Event Based
CCIS.
(1)
(2)
YYY=154
00-63: Trunk Route No.
5 : 3.1 kHz audio
6 : Speech
7 : Unrestricted digital information
NOTE: Can’t be used if opposite PBX
is a NEAX2400.
CM35
A
END