CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN-PRI Programming
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 69
DESCRIPTION DATA
NOTE 1: This data should be assigned to
the B channel trunk route. For
D channel trunk route, no data
setting is required.
NOTE 2: This data should be assigned to
both B channel trunk route and
D channel trunk route.
(1)
(2)
YY=16
Hooking Signal Sending to outside
00-63: B channel Trunk Route No.
0: Not sending
NOTE 1
(1)
(2)
YY=18 Digit conversion on DID call
00-63: B channel Trunk Route No.
0 : Provided
1 : Not provided
(1)
(2)
YY=19
00-63: B channel Trunk Route No.
0-3 : Programmable PAD
(See CM42)
4-7 : Fixed PAD
NOTE 1
NOTE: For details of PAD data, refer to
Command Manual.
(1)
(2)
YY=28 Outgoing Trunk Queuing
00-63: B channel Trunk Route No.
0: Restricted
NOTE 1
(1)
(2)
YY=39 Trunk release by detection of
reversal of tip and ring
00-63: B channel Trunk Route No.
1 : To release
NOTE 1
(1)
(2)
YY=89 CRC error check
00-63: B channel Trunk Route No.
0: Provided
NOTE 1
(1)
(2)
YY=90 Assignment of DTI route for
ISDN
00-63: B channel/D channel Trunk
Route No.
3: ISDN-Primary Rate Interface
NOTE 2
CM35