NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
39
4.4 About BMC Configuration
4.4.1 About BMC Configuration tool
Among the BMC configuration information tools there are some tools which cannot be used to setup
ESMPRO.
-- NEC MWA Agent cannot be used.
-- If the DianaScope is not stored in the NEC EXPRESSBUILDER CD-ROM, “A setup of a system
management” stored in the CD-ROM cannot be used.
-- The Console-less function of the NEC EXPRESSBUILDER can be used only when ESMPRO is stored in
the same NEC EXPRESSBUILDER CD-ROM.
4.4.2 In Case of Exchange of management PC
If a management PC as an alert receiver has been exchanged, register the managed component’s BMC
configuration information again even when the IP address of the management PC remains unchanged.
Otherwise, the BMC may fail to recognize the alert receiver.
4.4.3 About the function “Obtain an IP Address automatically (DHCP)
The managed component included the BMC that uses a Management LAN port supports the function “Obtain
an IP Address automatically (DHCP)”.
(1) Following version of NEC ESMPRO Manager modules supports the setting of the function.
Managed component DianaScope
DianaScope Agent Ver.2.03.05 and above The managed component that integrates
EXPRESSSCOPE Engine series.
DianaScope Configuration Ver.1.02 and above
DianaScope Agent Ver.2.06.00 and above The managed component installed
Advanced Remote Management Card.
DianaScope Configuration Ver.1.02 and above
When you use the module that does not support the setting of the function “Obtain an IP Address
automatically (DHCP)” for the managed component that supports the function, please note followings:
-- If DianaScope Agent does not support the setting of the function, the DianaScope Agent always set
“disable” for the function when it registers the BMC configuration. The DianaScope Agent also set
“disable” when it writes the BMC configuration information file.
-- If DianaScope Configuration does not support the setting of the function, the DianaScope Configuration
always set “disable” for the function when it writes the BMC configuration information file.
-- If “System Management” tool on NEC EXPRESSBUILDER does not support the setting of the function,
the tool always set “disable” for the function when it registers the BMC configuration. The tool also set
“disable” when it writes the BMC configuration information file.
-- If remote console feature of NEC EXPRESSBUILDER does not support the setting of the function, the
tool always set “disable” for the function when it registers the BMC configuration.
(2) If the managed component has been installed Advanced Remote Management Card, the BMC may not
immediately obtain the IP address after DianaScope PXE Service configures the BMC to obtain the IP
address by the DHCP. Please turn the managed component AC-OFF and then AC-ON because the BMC try
to obtain the IP address whenever the managed component is turned AC-ON.