NEC Express5800/R120f-1M Przewodnik Instalacji Strona 297

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 344
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 296
6. Setting Up Windows Server 2008
Express5800/R120f-1M, R120f-2M Installation Guide (Windows)
297
Chapter 1 Installing Windows
8. When configuring LiveLink, select Yes, click Next, and then go to step 9.
When configuring LiveLink is unnecessary, select No, click Next, and then go to step 15.
9. You can use the default setting for Probe interval and Probe maximum retries. If you change these
values, select a value from each drop-down list, click the target probe (Probe Target xx), and then click
Edit Target IP Address.
Tips
The setting range of Probe interval (link packet transmission interval) is 1 to 60
(units: seconds).
The setting range of Probe maximum retries (link packet retry count) is 1 to 10
(times).
Switching a path upon detection of a communication path error by LiveLink
takes (Probe maximum retries + 1) x Probe interval (seconds) at maximum.
If a link down is detected, failover occurs immediately after the link goes down. It
takes the time specified for Probe interval (seconds) to recover from the link
going down.
When using Tagged VLAN, input the VLAN ID for Probe VLAN ID.
Przeglądanie stron 296
1 2 ... 292 293 294 295 296 297 298 299 300 301 302 ... 343 344

Komentarze do niniejszej Instrukcji

Brak uwag