NEC Display Wall Calibrator Podręcznik Użytkownika Strona 55

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 54
55 | NEC DISPLAY WALL CALIBRATOR - USER’S GUIDE
This panel shows the measured White Point values from the
color sensor taken during the Measurement and Calibration
operations. Both the White Point and Intensity (luminance) are
shown as numerical values and graphically.
The White Point shows the measured value compared to the
Target White Point in CIE xy.
This gives an indication as to the accuracy of the calibration
compared to the Target value, as well as how far the display
needed to be adjusted from the native state in order to achieve
the Target White Point.
The Intensity bar shows the measured value. If the Target is a
specic value, then red arrows indicate this level on the bar.
Uncalibrated - Shows the native or un-calibrated measurement
taken during the Measure operation.
Calibrated - Shows the corrected or calibrated measurement
taken during the Calibration operation.
Display Measurements panel
Przeglądanie stron 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 91 92

Komentarze do niniejszej Instrukcji

Brak uwag