NEC ESMPRO Manager Setup Guide
11
CHECK:
If a managed component supports SOL and "Redirection" is selected to "Enable", you
must change the following items for the remote console via the LAN.
"Configuration" page – "System BIOS" page – "Flow Control": Hardware
RTS/CTS.
Select "Apply".
The configuration information is set in the BMC.
Select "Property" page in "Network" screen.
Set the following items. The other items can be used with the default values.
-- "DHCP"
Determine whether to dynamically obtain an IP address from a DHCP server.
If the item is set Enable and applied, BMC set the value obtained from DHCP server on "IP Address",
"Subnet Mask" and "Default Gateway".
-- "IP Address"
Enter the BMC IP address.
-- "Subnet Mask"
Enter the subnet mask for the IP address.
-- "Default Gateway"
Enter the default gateway if the managed component connects to management PC via any gateway
The following screen shows example.
If you set "Default Gateway", confirm that the gateway is connected to network.
Select "Apply".
The configuration information is set in the BMC.