NEC ESMPRO Manager Setup Guide
50
CHECK:
The "LAN2" in "BMC Configuration" screen is displayed only when the managed
component's BMC supports communication via LAN2. To communicate with the
NEC ESMPRO Manager via LAN2, make the setting on the "LAN2" and
"LAN2(Alert)" as same as "LAN1" and "LAN1(Alert)".
If you set "Default Gateway", please connect the managed component via LAN port used by BMC and
the gateway to network.
If you set "Alert Receiver / Management PC IP Address" on same network with the managed
component, please connect the managed component via LAN port used by BMC and the alert
receiver/management PC to network.
Select "Save BMC Configuration" from "BMC Configuration" screen.
The configuration information will be set in the BMC. The MAC addresses of the gateway and the alert
receivers will be also set in the BMC.