NEC ESMPRO Manager Setup Guide
28
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the IP address of the
management LAN port for the Standby BMC to the form.
Subnet Mask1 Enter the subnet mask that is specified on LAN2 of the BMC
configuration for the managed component.
If the managed component is a fault tolerant server, you should enter the
subnet mask of the management LAN port for the CPU/IO module 1 to
the form.
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the subnet mask of the
management LAN port for the Standby BMC to the form.
CHECK:
*1 If NEC ESMPRO Manager is installed on Linux system, “SNMP” is not supported.
CHECK:
*2 If a self-signed certificate is installed on the managed server for HTTPS
communication, a setting to allow it is required. Refer to “1.1 Setup Flow” for
detailed information.
CHECK:
*3 Regarding a port number for WS-Man communication, refer to “Appendix C. Port
number for WS-Man communication”.
IMPORTANT:
If BMC(EXPRESSSCOPE Engine) management is disabled, NEC ESMPRO Manager
may not be able to monitor HW status. Detailed information is shown in the
connection check result screen.