GammaCompMD QA Client User Manual
Copyright © NEC Display Solutions Ltd., 2006 -2015 7
About GammaCompMD QA Client
GammaCompMD QA is a Display Maintenance and Quality Assurance system specifically
developed to maintain Diagnostic Imaging Displays in a Medical Environment and ensure
compliance with Digital Imaging and Communications in Medicine Grayscale Standard
Display Function (DICOM GSDF).
GammaCompMD QA Client is the part of this system which is installed and used on
workstations with NEC diagnostic imaging displays and review display in PACS environments.
GammaCompMD QA Client can be used stand-alone as well as in a networked Display
Maintenance and Quality Assurance environment and allows a user to:
Check display status current luminance, active backlight hours and remaining backlight
lifetime, display temperature and other hardware status information
Check PACS display information - serial number and asset ID, DICOM conformance and
historical status data of the connected displays
Perform conformance check and re-calibration to DICOM
Check luminance uniformity across the display surface
Match pairs of displays - Luminance and Color matching to other displays in the field
Copy display performance settings from one display to another
Automate maintenance - schedule calibrations and conformance tests
Generate reports of QC tests performed - following AAPM TG18, ACR AAPM SIIM,
and JESRA X-0093 guidelines as well as regional support for DIN V 6868-57, DIN
6868-157 and IEC 62563-1.
Different user levels
GammaCompMD QA Client features an intuitive user interface with three different
customizable user levels. The Advanced user level contains access to the complete menu and
configuration structure, and is aimed at expert users, PACS administrators and Service
Providers. A second Technician user level has slightly restricted menu options, which are
suited to medical physicists and radiographers who need to carry out conformance checks
and QA tests. The final Radiologist user level is aimed at Radiologists with visual tests, to
confirm the DICOM compliance of the display quickly.
Automated Procedures
GammaCompMD QA Client provides a high level of automated procedures. While the Auto
Mode for a simplified calibration routine and Scheduled Tests ensure a more productive
work process, automated data backup increases data safety and QA peace of mind.